Battery Backup UPS 300-1000 Watts -120v 15 Amp 6-8 Receptacles,NEMA 5-15R-Surge-protected,RJ-45 Modem/Fax/10Base-T,4 LEDs indicators,Warranty 2-3yrs.
National Computer Solutions Banner HOME Contact us About Us SITE MAP NCS EMAIL Address

                 Home

  
 Cable Management

    Cabinets

   
Environmental Sensors

  Fans - 110 Volt

  Hardware-Screws & Nuts

  KVM Switch

 
 Lan Racks

  
LCD Monitor Keyboard

   LCD Rackmount Monitor

  
Patch Panels

   Power Strips - PDU

   Rack Frames

   Rackmount Shelves

   Relay Racks

   Storage Drawers

   UPS Back UP Power

   Wall Cabinets

   Wall Racks

  

 

Battery Backup UPS 750VA/450 Watts-120v,6 Receptacles,3 x NEMA 5-15R-Battery Backup System,3 x NEMA 5-15R-Surge-protected,RJ-45 Modem/Fax/10Base-T,4 LEDs indicators,Warranty 3yrs. Please contact us 866-431-3900 with your Powerstrip specifications.                        

                    
      
                                     UPS 750VA/450 Watts-120v,6 Receptacles,3 x NEMA 5-15R-Battery Backup System,3 x NEMA 5-15R-Surge-protected,RJ-45 Modem/Fax/10Base-T,4 LEDs indicators,Warranty 3yrs. UPS_Back_UP_Power
Credit Cards
120v Uninterrupted Power Supply - Battery Backup
Click Picture For Specifications
Order
Item Number
Description
Amps
Outlets
Price
NC-VRA550U  UPS 550VA/300 Watts,8 total NEMA 5-15R outlets, Two of which are widely spaced to accommodate large transformer plugs,4 outlets feature full battery support,4 additional outlets offer surge suppression only. Full load runtime 3 min. (300w),Half load runtime 9 min. (150w),2 LEDs indicate power status and overload/check battery status. NC-VRA550U  UPS 550VA/300 Watts,8 total NEMA 5-15R outlets, Two of which are widely spaced to accommodate large transformer plugs,4 outlets feature full battery support,4 additional outlets offer surge suppression only. Full load runtime 3 min. (300w),Half load runtime 9 min. (150w),2 LEDs indicate power status and overload/check battery status.



NC-VRA550U
Battery Backup UPS 550VA/300 Watts,8 total NEMA 5-15R outlets, Two of which are widely spaced to accommodate large transformer plugs,4 outlets feature full battery support,4 additional outlets offer surge suppression only. Full load runtime 3 min. (300w),Half load runtime 9 min. (150w),2 LEDs indicate power status and overload/check battery status.
3-year Limited Warranty
15
8
$89.00
NC-TRAMS750USB -UPS 750VA / 450 Watts -120V 6 Receptacles,

NC-TRAMS750USB
Battery Backup UPS 750VA / 450 Watts -120V 6 Receptacles,3 x NEMA 5-15R - Battery Backup System,
3 x NEMA 5-15R - Surge-protected,RJ-45 Modem/Fax/10Base-T, 4 LEDs indicators,
3 minutes battery runtime with a full load of 750VA/450 Watts and 11 minutes with a half load of 375VA/225 Watts.
Warranty 3yrs.
15
6
$160.00
NC-SVINMO800 UPS 800VA / 475 Watts -120V 7 Receptacles, NC-SVINMO800 UPS 800VA / 475 Watts -120V 7 Receptacles,

NC-SVINMO800 Battery Backup UPS 800VA / 475 Watts -120V 7 Receptacles, 6 x NEMA 5-15R - Battery Backup System,
1 x NEMA 5-15R - Surge-protected,Built-in single line RJ phone suppression jacks, 4 LEDs indicators,
6 minutes battery runtime with a full load of 800VA and 19 minutes with a half load of 400VA. Warranty 3yrs.
15
7
$155.00
NC-TRAMS1000LCD  UPS 1000VA / 500 Watts -120V 4 UPS outlets, 4 surge-only outlets,Built-in single-line RJ-11 phone suppression jacks, 4 LEDs indicators, 4 minutes full load runtime (1000VA / 500 Watts), 14 minutes half load runtime (500VA / 250 Watts)

NC-TRAMS1000LCD Battery Backup UPS 1000VA / 500 Watts -120V 4 UPS outlets, 4 surge-only outlets,Built-in single-line RJ-11 phone suppression jacks, 4 LEDs indicators, 4 minutes full load runtime (1000VA / 500 Watts), 14 minutes half load runtime (500VA / 250 Watts) Warranty 3yrs.
15
4
$169.00
NC-TRAMS500RT1U  UPS 500 VA/300 W, 7 total NEMA 5-15R outlets with one single outlet load bank that can be powered off and back on again via software interface. Simultaneous monitoring by up to 3 directly-connected devices through included USB, DB9 and SNMP. 1U rackmount installation in 2 or 4 post rack enclosures. Full load runtime 17 minutes at half load (250VA / 150 Watts) and 5 minutes at full load (500VA / 300 Watts), Built-in accessory slot supports SNMP with optional SNMPWEBCARD adapter. Multi-function audible alarms and set of 5 front panel LEDs. PowerAlert Software,

NC-TRAMS500RT1U Battery Backup UPS 500 VA/300 Watts, 7 total NEMA 5-15R outlets with one single outlet load bank that can be powered off and back on again via software interface. Simultaneous monitoring by up to 3 directly-connected devices through included USB, DB9 and SNMP. 1U rackmount installation in 2 or 4 post rack enclosures. Full load runtime 17 minutes at half load (250VA / 150 Watts) and 5 minutes at full load (500VA / 300 Watts), Built-in accessory slot supports SNMP with optional SNMPWEBCARD adapter. Multi-function audible alarms and set of 5 front panel LEDs. PowerAlert Software, 2yr. Warranty
15
7
$197.00
NC-TRAMS750RT1U  UPS 750 VA/450W, 6 NEMA 5-15R output receptacles arranged in 2 switchable single-outlet load banks. Network management interfaces includes USB port, DB9 serial port and SNMPWEBCARD slot. Supports simultaneous detailed monitoring of equipment load levels, self-test data and mains power conditions via all 3 network interfaces at once. 1U rackmount installation in 2 or 4 post rack enclosures. Half load runtime of 24 minutes (375VA / 225 Watts) / Full load runtime of 7 minutes (750VA / 450 Watts) Built-in accessory slot supports SNMP with optional SNMPWEBCARD adapter. Multi-function audible alarms and set of 5 front panel LEDs. PowerAlert Software, 2yr. Warranty NC-TRAMS750RT1U  UPS 750 VA/450W, 6 NEMA 5-15R output receptacles arranged in 2 switchable single-outlet load banks. Network management interfaces includes USB port, DB9 serial port and SNMPWEBCARD slot. Supports simultaneous detailed monitoring of equipment load levels, self-test data and mains power conditions via all 3 network interfaces at once. 1U rackmount installation in 2 or 4 post rack enclosures. Half load runtime of 24 minutes (375VA / 225 Watts) / Full load runtime of 7 minutes (750VA / 450 Watts) Built-in accessory slot supports SNMP with optional SNMPWEBCARD adapter. Multi-function audible alarms and set of 5 front panel LEDs. PowerAlert Software, 2yr. Warranty

NC-TRAMS750RT1U Battery Backup UPS 750 VA/450 Watts, 6 NEMA 5-15R output receptacles arranged in 2 switchable single-outlet load banks. Network management interfaces includes USB port, DB9 serial port and SNMPWEBCARD slot. Supports simultaneous detailed monitoring of equipment load levels, self-test data and mains power conditions via all 3 network interfaces at once. 1U rackmount installation in 2 or 4 post rack enclosures. Half load runtime of 24 minutes (375VA / 225 Watts) / Full load runtime of 7 minutes (750VA / 450 Watts) Built-in accessory slot supports SNMP with optional SNMPWEBCARD adapter. Multi-function audible alarms and set of 5 front panel LEDs. PowerAlert Software,
2yr. Warranty
15
6
$426.00
NC-TRAMS1000RM2U UPS 1000VA / 700 Watts, 6 NEMA 5-15R output receptacles arranged in 2 load banks that are individually controllable via software interface includes USB port, DB9 serial port and SNMPWEBCARD slot. Supports simultaneous detailed monitoring of equipment load levels, self-test data and mains power conditions via all 3 network interfaces at once. 2U rackmount installation in 2 or 4 post rack enclosures. Runtimes of 21 minutes at half load 500VA / 350 Watts and 9 minutes at full load 1000VA / 700 Watts. Built-in accessory slot supports SNMP with optional SNMPWEBCARD adapter. Multi-function audible alarms and set of 5 front panel LEDs. PowerAlert Software, 2yr. Warranty

NC-TRAMS1000RM2U UPS 1000VA / 700 Watts, 6 NEMA 5-15R output receptacles arranged in 2 load banks that are individually controllable via software interface includes USB port, DB9 serial port and SNMPWEBCARD slot. Supports simultaneous detailed monitoring of equipment load levels, self-test data and mains power conditions via all 3 network interfaces at once. 2U rackmount installation in 2 or 4 post rack enclosures. Runtimes of 21 minutes at half load 500VA / 350 Watts and 9 minutes at full load 1000VA / 700 Watts. Built-in accessory slot supports SNMP with optional SNMPWEBCARD adapter. Multi-function audible alarms and set of 5 front panel LEDs. PowerAlert Software,
2yr. Warranty
15
6
$470.00
NC-TRAMS1500RM2U Battery Backup UPS 1500VA/1000 Watts-120v, 8 NEMA 5-15R output receptacles arranged in 2 load banks that are individually controllable via software interface. 2U rackmount installation in 2 or 4 post rack enclosures. Runtimes of 19 minutes at half load 750VA / 500 Watts and 7 minutes at full load 1500VA / 1000 Watts. PowerAlert UPS monitoring and unattended shutdown software enables configurable network broadcast messaging, email notification, event logging and running user-defined script commands. Offers simultaneous monitoring by up to 3 directly-connected devices through included USB, DB9 and SNMP* interfaces (*requires optional SNMPWEBCARD), or the monitoring of any number of additional UPS systems over IP with included PowerAlert monitoring software. Communications ports support messaging of UPS and line power status, including on battery, low-battery, power restored, AC line voltage, DC battery voltage and remaining battery capacity. Built-in accessory slot supports SNMP with optional SNMPWEBCARD adapter. Multi-function audible alarms and set of 5 front panel LEDs. Emergency Power Off (EPO) interface with cable Network-grade AC surge suppression.  2yr. Warranty NC-TRAMS1500RM2U Battery Backup UPS 1500VA/1000 Watts-120v, 8 NEMA 5-15R output receptacles arranged in 2 load banks that are individually controllable via software interface. 2U rackmount installation in 2 or 4 post rack enclosures. Runtimes of 19 minutes at half load 750VA / 500 Watts and 7 minutes at full load 1500VA / 1000 Watts. PowerAlert UPS monitoring and unattended shutdown software enables configurable network broadcast messaging, email notification, event logging and running user-defined script commands. Offers simultaneous monitoring by up to 3 directly-connected devices through included USB, DB9 and SNMP* interfaces (*requires optional SNMPWEBCARD), or the monitoring of any number of additional UPS systems over IP with included PowerAlert monitoring software. Communications ports support messaging of UPS and line power status, including on battery, low-battery, power restored, AC line voltage, DC battery voltage and remaining battery capacity. Built-in accessory slot supports SNMP with optional SNMPWEBCARD adapter. Multi-function audible alarms and set of 5 front panel LEDs. Emergency Power Off (EPO) interface with cable Network-grade AC surge suppression.  2yr. Warranty

NC-TRAMS1500RM2U
Battery Backup UPS 1500VA/1000 Watts-120v, 8 NEMA 5-15R output receptacles arranged in 2 load banks that are individually controllable via software interface. 2U rackmount installation in 2 or 4 post rack enclosures. Runtimes of 19 minutes at half load 750VA / 500 Watts and 7 minutes at full load 1500VA / 1000 Watts. PowerAlert UPS monitoring and unattended shutdown software enables configurable network broadcast messaging, email notification, event logging and running user-defined script commands. Offers simultaneous monitoring by up to 3 directly-connected devices through included USB, DB9 and SNMP* interfaces (*requires optional SNMPWEBCARD), or the monitoring of any number of additional UPS systems over IP with included PowerAlert monitoring software. Communications ports support messaging of UPS and line power status, including on battery, low-battery, power restored, AC line voltage, DC battery voltage and remaining battery capacity. Built-in accessory slot supports SNMP with optional SNMPWEBCARD adapter. Multi-function audible alarms and set of 5 front panel LEDs. Emergency Power Off (EPO) interface with cable Network-grade AC surge suppression.
2yr. Warranty
15
8
$590.00
RKP115-801 NC-TRAMS750USB UPS 750VA/450 Watts-120v,6 Receptacles,3 x NEMA 5-15R-Battery Backup System,3 x NEMA 5-15R-Surge-protected,RJ-45 Modem/Fax/10Base-T,4 LEDs indicators,Warranty 3yrs.. Please conact us Toll Free at 866-431-3900 for additional information.
UPS 750VA / 450 Watts -120V 6 Receptacles, NC-TRAMS1000LCD  UPS 1000VA / 500 Watts -120V 4 UPS outlets, 4 surge-only outlets,Built-in single-line RJ-11 phone suppression jacks, 4 LEDs indicators, 4 minutes full load runtime (1000VA / 500 Watts), 14 minutes half load runtime (500VA / 250 Watts) NC-TRAMS500RT1U  UPS 500 VA/300 W, 7 total NEMA 5-15R outlets with one single outlet load bank that can be powered off and back on again via software interface. Simultaneous monitoring by up to 3 directly-connected devices through included USB, DB9 and SNMP. 1U rackmount installation in 2 or 4 post rack enclosures. Full load runtime 17 minutes at half load (250VA / 150 Watts) and 5 minutes at full load (500VA / 300 Watts), Built-in accessory slot supports SNMP with optional SNMPWEBCARD adapter. Multi-function audible alarms and set of 5 front panel LEDs. PowerAlert Software, NC-TRAMS1000RM2U UPS 1000VA / 700 Watts, 6 NEMA 5-15R output receptacles arranged in 2 load banks that are individually controllable via software interface includes USB port, DB9 serial port and SNMPWEBCARD slot. Supports simultaneous detailed monitoring of equipment load levels, self-test data and mains power conditions via all 3 network interfaces at once. 2U rackmount installation in 2 or 4 post rack enclosures. Runtimes of 21 minutes at half load 500VA / 350 Watts and 9 minutes at full load 1000VA / 700 Watts. Built-in accessory slot supports SNMP with optional SNMPWEBCARD adapter. Multi-function audible alarms and set of 5 front panel LEDs. PowerAlert Software, 2yr. Warranty